Tech Briefs

Measuring Radiation Patterns of Reconfigurable Patch Antennas on Wafers

Tests can be performed relatively inexpensively and without sawing wafers.

An apparatus and technique have been devised for measuring the radiation pattern of a microwave patch antenna that is one of a number of identical units that have been fabricated in a planar array on a high-resistivity silicon wafer. The apparatus and technique are intended, more specifically, for application to such an antenna that includes a DC-controlled microelectromechanical system (MEMS) actuator for switching the antenna between two polarization states or between two resonance frequencies.

Prior to the development of the present apparatus and technique, patch antennas on wafers were tested by techniques and equipment that are more suited to testing of conventional printed-circuit antennas. The techniques included sawing of the wafers to isolate individual antennas for testing. The equipment included custom-built test fixtures that included special signal launchers and transmission-line transitions. The present apparatus and technique eliminate the need for sawing wafers and for custom-built test fixtures, thereby making it possible to test antennas in less time and at less cost. Moreover, in a production setting, elimination of the premature sawing of wafers for testing reduces loss from breakage, thereby enhancing yield.

ImageThe apparatus includes (1) a commercial coplanar-waveguide ground-signal-ground radio-frequency (RF) probe, through which microwave excitation is applied to a microstrip transmission line that is part of the integrated circuitry of the patch antenna under test; (2) DC probes for biasing the microelectromechanical actuator; (3) a spinning linearly polarized antenna for sampling the linearly and circularly polarized radiation from the patch antenna as a function of angle relative to the perpendicular to the plane of the wafer; and (4) an automatic network analyzer/microwave receiver for measuring the sampled signal. The microwave probe is a commercial unit of the coplanar-waveguide (CPW) ground-ground-signal-ground type. The microwave and DC probes (see Figure 1) are installed in a commercial RF wafer probe station that has been modified to accommodate the rotating sampling antenna.

ImageThe sampling antenna (see Figure 2) is an open-ended rectangular waveguide that is spun by use of a small DC motor mounted on poly (methyl methacrylate)arm. The signal acquired by the sampling antenna is coupled through a coaxial rotary joint to a detector that is also mounted on the arm. The arm, in turn, is attached to the shaft of a stepping motor, which is used to position the sampling antenna, in increments of a few degrees, along an arc that extends from -90° to +90° relative to the perpendicular to the plane of the wafer.

This work was done by Rainee N. Simons of Glenn Research Center. For further information, access the Technical Support Package (TSP) free on-line at www.techbriefs.com/tsp under the Electronics/Computers category. Inquiries concerning rights for the commercial use of this invention should be addressed to NASA Glenn Research Center, Commercial Technology Office, Attn: Steve Fedor, Mail Stop 4-8, 21000 Brookpark Road, Cleveland Ohio 44135. Refer to LEW-17462.

This Brief includes a Technical Support Package (TSP).

Measuring Radiation Patterns of Reconfigurable Patch Antennas on Wafers (reference LEW-17462) is currently available for download from the TSP library.

Please Login at the top of the page to download.