Wilcoxon Research (Gaithersburg, MD) has introduced the 788A accelerometers that feature a sensitivity of 100 mV/g. The accelerometer is a single-axis sensor with an acceleration range of +50 g. High-frequency response measurements up to 10 kHz identify faults and improper machine operation. Typical noise is 4 mg at 100 Hz. The unit operates at temperatures between -50 and 120 °C. Applications include vibration monitoring of fans, motors, pumps, blowers, compressors, chillers, gearboxes, and mixers.


Motion Control Technology Magazine

This article first appeared in the April, 2006 issue of Motion Control Technology Magazine.