Magnetic-field-response sensors have been developed for use in measuring levels of fluids under extreme conditions. The sensors work without wire connections or direct physical contact with power sources, microprocessors, data- acquisition equipment, or electrical circuitry. For fuel-level sensors, the absence of wire connections offers an important safety advantage in elimination of potential ignition sources.


The sensor is interrogated by use of the system described in “Magnetic-Field-Response Measurement-Acquisition System” (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006) page 28. To recapitulate: The system includes a transmitting/receiving antenna that is placed in proximity to the inductor. The system generates a series of increasing oscillating magnetic field harmonics that powers the sensors. Once powered, the sensors respond with their own oscillating magnetic fields. The system measures the response of the sensor circuitry to excitations at different frequencies to identify the resonance frequency. Hence, once calibration data of liquid level versus resonance frequency have been acquired (see Figure 2), the sensor can be used as a fluid-level sensor.
This work was done by Stanley E. Woodard of Langley Research Center and Bryant D. Taylor of Swales Aerospace.